12
IROutputPower
SetIROutputPowerLevelforeachIRport(exceptIRPort1)
LImportant
Please make sure that the “End point selection control” has
completed(ifnecessary)beforeprocessthefollowingsetup.
Step SetupKey
LEDIndication
Statuson
ZXT310
1
MakesureZXT310switchedto
Channel1(EP1)
LEDflashes
oncethen
keepon
2
Refertoyourprimarycontroller
instructionstoprocessthe
configurationsetupprocedure.
‐Parameter:28(0x1C)
‐Value:255(0xFF)
SetIRoutputpowerlevelbyentering
0(0x00)Normalpowermode
255(0xFF)Highpowermode
(defaultisinhighpowermode)
‐
3
PressthePROGbuttonon
ZXT310
LEDflashes
twicethen
keepon
SetIRPower
level
successful
Note 1: Red LED flashes 6 times means that the setup process is failed.
Please redo the process again.
Note 2: IR port 1 is a fixed IR output power which is un-configurable
and operating in wide angle and long distance coverage.